Secured Trading Service

35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs

Yueqing Liyond Electric Co., Ltd.
  • Audited Supplier
  • 18 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Three-position design integrates closing, opening, and earthing states in a single epoxy resin shell to prevent manual maloperation during switchgear maintenance.
  • APG cast epoxy resin encapsulation ensures full insulation and dual-break rotary moving contact configuration for reliable 36kV power frequency withstand voltage.
  • Gas tightness control retains internal SF6 gas pressure at 0.04-0.05 MPa with an annual leakage rate below 0.5%, minimizing internal flashover risks.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of 35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs

35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs pictures & photos
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs pictures & photos
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs pictures & photos
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs pictures & photos
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs pictures & photos
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs pictures & photos
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
  • 35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
  • 35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
    35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
  • 35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
    35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
  • 35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
    35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
  • 35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
    35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
  • 35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
    35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
  • 35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
    35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs

Find Similar Products

Product Description

35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs

35kV RMU SF6 Load Break Switch Indoor Branch Type LBS

35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
The sf6 load break switch is suitable for closing and breaking load currents and overload currents in the ring network power supply or double amplitude power supply system of three-phase AC 50/60Hz, rated voltage 24/40.5kV, and can also be used for closing and breaking no-load long lines, no-load transformers and capacitor banks, etc. The combination of load switch and current-limiting fuse in series can be used instead of circuit breaker, i.e. the load switch is responsible for closing and breaking various load currents, while the current-limiting fuse is responsible for breaking larger overload currents and short-circuit currents.

 

Features.
1. Good insulation performance, the load switch is sealed by the epoxy resin casted upper and lower enclosure, the main circuit and grounding circuit system are all placed inside the shell.
2. Good safety performance, if an internal burning arc occurs, there is a structural weak point at the back of the shell, it will be flushed open, and then the arc relief valve above the cabinet flushes open and directs the overpressure airflow outside the cabinet.
3. Manual and electric operation are available, easy and reliable to operate.
4.Three-phase overall installation, good periodicity, small number of parts, easy to adjust and install, simple and easy, maintenance-free, long life.

 

Normal working Environment

 1. Altitude: ≤1000m

 2. Ambient temperature at -30ºC to +40ºC, the daily average temperature should not more than 30ºC.

 3. The daily average of relative humidity is less than 95%, the average monthly is less than 90%.

 4. Working environment should be without steam, gas, chemical corrosive deposition, salt fog, dust, dirt and other dangerous explosive media, which will severely impact on insulation and conductivity of products.

 5. Working environment should not be regular vibration or serious bumps.


35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs

Drawing
 
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
 
35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs

35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs
FAQ

 

35kv 36kv Rmu Sf6 Load Break Switch Indoor Branch Type Lbs

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASI223330". Items marked "verified" are certified.

Watch Video
Watch Video
Yueqing Liyond Electric Co., Ltd.
Yueqing Liyond Electric Co., Ltd.
Yueqing Liyond Electric Co., Ltd.
Yueqing Liyond Electric Co., Ltd.
Yueqing Liyond Electric Co., Ltd.
Yueqing Liyond Electric Co., Ltd.
Yueqing Liyond Electric Co., Ltd.
Yueqing Liyond Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
Room 1801, building 2, 3 and 4, headquarters economic Park, No. 6688, Xuyang Road, Chengdong street, Yueqing City, Zhejiang Province
verified Plant Area
1100 square meters
verified Number of Employees
18
verified Registered Capital
5,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Ningbo Port, Shanghai Port

Our Production Capability & Technical Expertise

verified Main Products
Medium and High Voltage Switchgear, Switchgear Accessories, Vacuum Vircuit Breaker, Vacuum Circuit Breaker Accessories, Earthing Switch, Load Break Switch, Auxiliary Switch, Conductive Parts, Insulation Parts
verified R&D Engineers
2 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2011-04-07
Export Year
2011-04-07
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea)
verified Number of Foreign Trading Staff
7
verified Overseas Agent/Branch
No

Our Certifications, Standards & Industry Recognition

verified Product Certification
CE

FAQ

What is the rated short-time withstand current for this 36kV Load Break Switch?
The FLN36-35 36kV Load Break Switch provides a rated short-time withstand current of 20kA for a 3-second duration, and a rated peak withstand current of 50kA, ensuring stability under fault conditions in 35kV RMU switchgear.
How does the integrated earthing switch ensure interlocking safety in the Ring Main Unit Switch?
This Three Position LBS utilizes a single shared spring operating mechanism that mechanically interlocks the "Close, Open, and Earth" positions. The mechanism physically blocks simultaneous engagement of the main switch and the earthing circuit.
Can the manual operating mechanism of this SF6 Switch Disconnector be upgraded to motorized operation?
Yes. This SF6 Switch Disconnector supports both standard manual spring operation and motorized installation. An external AC/DC 220V electric motor mechanism can be factory-fitted to enable remote control.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now