Yueqing Liyond Electric Co., Ltd. presents the FN18 series Indoor High Voltage Load Break Switch with Nalf Air Insulation. Ideal for medium voltage applications, this 630A switch combines breaker fuses for efficient operation.
Introducing the FN18 series indoor high-voltage load switch from Yueqing Liyond Electric Co., Ltd. This three-pole, load break switch is designed to provide switchgear owners and assemblers with advanced interrupting technology and reliable performance in a compact design.
The FN18 series is ideal for city network construction, high-rise buildings, ring network power supply, and box-type substation and transformer protection.
AC 50Hz, rated voltage 12kV, 24kV, rated current 630A
Rated voltage | Unit | 12kV | 17.5kV | 24kV | 36kV | 40.5kV | |||||||||||
Rated current | A | 400 | 630 | 1250 | 400 | 630 | 1250 | 400 | 630 | 1250 | 630 | 800 | 1000 | 630 | 800 | 1000 | |
Max. rated current | A | 400 | 630 | 1250 | 400 | 630 | 1250 | 400 | 630 | 1250 | 630 | 800 | 800 | 630 | 800 | 800 | |
Short circuit making capacity | KA peak | 67 | 50 | 50 | 50 | 50 | |||||||||||
Peak withstand current | KA peak | 82 | 82 | 82 | 66 | 66 | |||||||||||
Short time current | 1 sec. | KA eff |
31.5 25 20 |
31.5 25 20 |
31.5 25 20 |
31.5 25 |
31.5 25 |
31.5 25 |
25 25 16 |
25 25 16 |
31.5 25 16 |
25 | 25 | 25 | 25 | 25 | 25 |
2 sec. | |||||||||||||||||
3 sec. | |||||||||||||||||
Mainly active load breaking capacity 21 (test duty 1 and, IEC 60265-1( 265)) | A | 400 | 630 | 1250 | 400 | 630 | 1250 | 400 | 630 | 1250 | 630 | 800 | 630 | 800 | 630 | 800 | |
Mainly capacitive breaking capacity (test duty 4, IEC 60265-1 (IEC 265)) | A | 150 | 45 | 80 | 50 | 50 | |||||||||||
Mainly inductive breaking capacity cosφ=0.15 | A | 16 | 16 | 16 | 16 | 16 | |||||||||||
Max. breaking capacity in co-operation with fuses IEC 62271-105(IEC 420 1990-11) | A | 1600 | 1600 | 1600 | 1600 | 900 | 900 | 300 | 300 | 300 | 300 | 300 | 300 | ||||
Power frequency withstand voltage 50 Hz 1 min. -to earth and between poles -across isolating distance |
kV |
42 45 |
45 60 |
55 70 |
80 88 |
95 120 |
|||||||||||
Impulse withstand voltage 1.2/50 μs - to earth and between poles - across isolating distance |
kV |
75 85 |
95 110 |
125 145 |
170 195 |
190 220 |
|||||||||||
Pole distance | mm | 150, 170, 210 | 170, 210 | 170, 235, 275 | 360 | 360 | |||||||||||
Max. operating torque at: -closing K/A mech. -opening K/A mech. |
Nm | 115-120 Nm K-mech.120 Nm/A-mech. 3Nm |
80-100 Nm K-mech.80-100 Nm |
||||||||||||||
Operating angle on the shaft | degree | 130 | 120 | ||||||||||||||