• 10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel
  • 10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel
  • 10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel
  • 10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel
  • 10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel
  • 10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel

10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Handcart Type
Structure: Vsg Spring Operating Mechanism
Customization:
Diamond Member Since 2009

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
VSG-12
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000
Product Name
Vacuum Circuit Breaker
Rated Voltage
12kv
Rated Current
630A
Application
Indoor Switchgear
Spring Operating Mechanism
Vsg Type
Arc-Extinguishing
Vacuum
Pole Distance
210mm
Warranty
12 Months
Transport Package
Standard Export Packaging
Trademark
Liyond
Origin
China
Production Capacity
10000 Set/Month

Product Description

10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel


10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel
Vacuum circuit breaker is the most commonly used type of high-voltage circuit breaker, mainly divided into two kinds of indoor and outdoor. We mainly focus on indoor vacuum circuit breakers. (Indoor circuit breakers: High-voltage circuit breakers that do not have the performance of protection against wind, rain, snow, ice and dense frost, etc. and are suitable for installation and use inside buildings.)


The vacuum circuit breaker is named after its interrupting medium and the insulating medium of the contact gap after interrupting is high vacuum; it has the advantages of small size, light weight, suitable for frequent operation and interrupting without maintenance, and is more popularly used in the 3kV-40.5kV distribution network.

 

The components of vacuum circuit breaker are vacuum interrupter, electromagnetic or spring-operated mechanism, bracket and other parts.


Vacuum interrupter is the core component of vacuum circuit breaker, its main role is, through the excellent insulation of the vacuum inside the tube to make the medium and high voltage circuit cut off the power can quickly extinguish the arc and suppress the current to avoid accidents and accidents.


There are two kinds of operating mechanism: spring-operated mechanism and permanent magnetic operating mechanism.


The conductive circuit is divided into insulated cylinder form (vacuum interrupter is installed in the insulated cylinder) and sealed pole form (vacuum interrupter is installed in the epoxy resin).

The VSG mechanism uses a cam (in the core module of the mechanism) to drive the spindle directly (in the frame spindle module) to reduce the transmission link and improve the transmission efficiency (no hinge connection). Reduce the energy input of the product and increase the service life of the product. Install the main circuit module, that is, complete the basic configuration of the vacuum circuit breaker. Then install the chassis car module, the contact arm, the contact, and the insulating sleeve to complete the configuration of the hand-cranked circuit breaker.
 

Ambient condition

1. The ambient air temperature does not exceed 40ºC, and the average value measured within 24h does not exceed 35ºC.
2. The minimum ambient air temperature is -5ºC for the "-5 indoor" level, -15ºC for the "-15 indoor" level and -25ºC for the "-25 indoor" level. 15ºC, and -25ºC for the "-25 house" level.
3. The effect of sunlight radiation can be ignored.
4. The altitude does not exceed 1000m.
5. The surrounding air is not significantly contaminated by dust, smoke, corrosive and/or flammable gases, vapors or salt spray.


 

Technical features 

1.The first generation of the builtin type handcart in China with independent intellectual rights .It features a matured technology and high price/performance ratio .
2.The key parts adopt nickel-phosphorous alloy plating with perfect wear resistance and corrosion resistance .
3.The key parts are made by ourselves to ensure the products to meet the designing requirement of design
4.The cylindrical composite insulation main circuit features small volume,free of maintenance and few service.



Drawing

10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel


10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel

10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel
10kv 11kv 12kv Vsg Types of Vacuum Circuit Breaker Vcb Panel

FAQ:
Q: Could I have prices of your products?
A: Welcome. Please feel free to send us inquiry here. We will reply you within 24 hours.

Q: Can I get a sample before the bulk order?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.

Q: Can we print our logo/ company name on products?
A: Yes, of course, we accept OEM, then need you to provide brand authorization to us.

Q:Do you accept product customization?
A:Yes, of course, please provide specific drawings or parameters, we will quote you after evaluation.

Q: What is the lead time? 
A: The lead time depends on the quantities ordered, generally within 7-20 days after receiving the payment. 

Q: What is your Trade Terms? 
A: We accept EXW, FOB, CIF, FCA, etc. 

Q: What is your payment method?  
A: We accept T/T, Western Union, Paypal, etc.

Q: Do you inspect the finished products?
A: Yes, each step of production and finished products will be came out inspection by QC department before shipping. And we will provide goods inspection reports for your reference before shipment

Q: How to solve the quality problems after sales? 
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2009

Suppliers with verified business licenses

Trading Company
Number of Employees
18
Year of Establishment
2011-04-07