Zn85-40.5 Circuit Breaker Hand Truck PT Trolley for Kyn61 Switchgear

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
18
Year of Establishment
2011-04-07
Find Similar Products
  • Overview
  • FAQ
Overview

Basic Info.

Model NO.
ZN85-40.5
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
Vcb
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, Do as Your Request
Certification
ISO9001-2000, CE
Rated Voltage
40.5kv
Rated Frequency
50/60Hz
Rated Current
630A
Pole Distance
280mm
OEM
Accept
Transport Package
Wooden Case
Specification
steel, metal, ceramic, etc
Trademark
LIYOND
Origin
China
Production Capacity
10000/Month

Product Description

Zn85-40.5 Circuit Breaker Hand Truck PT Trolley for Kyn61 SwitchgearZn85-40.5 Circuit Breaker Hand Truck PT Trolley for Kyn61 Switchgear
ZN85-40.5 Circuit Breaker Hand Truck PT Trolley For KYN61 Switchgear 
Zn85-40.5 Circuit Breaker Hand Truck PT Trolley for Kyn61 Switchgear
The ZN85-40.5 PT Trolley is designed specifically for 1200mm width switchgear as a potential transformer (PT) trolley without an operating mechanism.
Unlike vacuum circuit breakers, which include mechanisms for switching and protection, this trolley is dedicated to holding and moving the PT and does not perform switching operations itself. Therefore, it lacks an integrated operating mechanism.

Primary Function:
It is used to house and maneuver potential transformers in high-voltage switchgear systems. Potential transformers are crucial for voltage measurement and system protection by providing scaled-down voltage readings to control systems.

Switchgear Compatibility:
Specifically designed to fit into 1200mm width switchgear like KYN61-40.5 or similar models, the PT trolley meets relevant standards such as IEC 62271 and GB/T 11022. These standards ensure that the trolley is safe, reliable, and suitable for high-voltage electrical applications.

Application in Power Systems:
PT trolleys are commonly used in power plants, substations, and industrial enterprises for voltage measurement, overload protection, and ensuring electrical safety during system maintenance. The handcart design allows for smooth, secure insertion and removal of PTs, ensuring the system operates efficiently without interrupting power.

Interlocking and Safety:
It features mechanisms to prevent misoperation, offering protection during maintenance or when PTs are being removed or inserted.

Technical Standards:
The trolley adheres to specifications like:
Rated voltage: 40.5 kV
Power frequency withstand voltage: 95 kV
Lightning impulse withstand voltage: 185 kV
Applicable environments: Temperature range of -40°C to +40°C, with a maximum altitude of 1000 meters

 

 

Drawing

Zn85-40.5 Circuit Breaker Hand Truck PT Trolley for Kyn61 Switchgear


Zn85-40.5 Circuit Breaker Hand Truck PT Trolley for Kyn61 SwitchgearZn85-40.5 Circuit Breaker Hand Truck PT Trolley for Kyn61 SwitchgearZn85-40.5 Circuit Breaker Hand Truck PT Trolley for Kyn61 SwitchgearZn85-40.5 Circuit Breaker Hand Truck PT Trolley for Kyn61 SwitchgearZn85-40.5 Circuit Breaker Hand Truck PT Trolley for Kyn61 SwitchgearZn85-40.5 Circuit Breaker Hand Truck PT Trolley for Kyn61 Switchgear

FAQ

Q: Could I have prices of your products?

A: Welcome. Please feel free to send us inquiry here. We will reply you within 24 hours.

 

Q: Can I get a sample before the bulk order?

A: Yes, we welcome sample order to test and check quality.Mixed samples are acceptable.

 

Q: Can we print our logo/ company name on products?

A: Yes, of course, we accept OEM, then need you to provide brand authorization to us

 

Q:Do you accept product customization?

A:Yes, of course, please provide specific drawings or parameters, we will quote you after evaluation


Q: What is the lead time? 
A: The lead time depends on the quantities ordered, generally within 7-20 days after receiving the payment. 

 

Q: What is your Trade Terms? 
A: We accept EXW, FOB, CIF, FCA, etc

 

Q: What is your payment method?  
A: We accept T/T, Western Union, Paypalirrevocable L/C at sight, etc 

 

Q: Do you inspect the finished products?

A: Yes, each step of production and finished products will be came out inspection by QC department before shipping. And we will provide goods inspection reports for your reference before shipment


Q: How to solve the quality problems after sales? 
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier