Basic Info.

Model NO.
FLN36-12
Usage
as Specification
Contact Type
as Specification
Detection Method
as Specification
Pole
3
Rated Continuous Current
630A
Number of Switch
as Specification
Brand
Liyond
Certification
ISO9001
Product Name
Sf6 Load Break Switch
Voltage Level
Medium Voltage
Work Position
Closed, Open, Earth
Phase Distance
200mm
Rated Voltage
12kv
Rated Current
630A
Rated Short Circuit Breaking Current
20ka
Mechanism Type
Manual
Transport Package
Standard Export Packaging
Specification
as specification
Trademark
Liyond
Origin
China

Product Description

12kv 200mm 3 Phase Switch with Manual Operating Mechanism Sf6 Lbs Air Load Break Switch

 

12kv 200mm 3 Phase Switch with Manual Operating Mechanism Sf6 Lbs Air Load Break Switch
FLN36-12kV SF6 load break switch is a switch equipment for medium voltage switchgear, using SF6 gas as arc extinguishing and insulating medium. There are three working positions: open, closed, earth position in the switch. The compact size, easy installation, and fine adaptability to environment make the switch suitable for many different applications.
It can be divided into two types: FLN36-12D ( K type single spring operating mechanism ), FLRN 36-12D (A type double spring operating mechanism). The latter type could be equipped with fuse combination, having control and protecting function, which can be used for power supply and substation as a protecting and control device, especially suitable for ring main unit, cable distribution box and switching substation.
 

Parameters
Item
Unit
Data
FLN36-12D/T630-20 
Load break switch
FLRN36-12D/125-50
LBS + Fuse-combination units
Rated voltage
kV
12
12
Rated frequency
Hz
50
50
Rated current
A
630
125
Short-duration(1min) power frequency withstand voltage
kV
42
42
Lightning impulse withstand voltage
kV
75
75
Rated power frequency withstand voltage(5min)
kV
24
24
Rated short-time withstand current(Load break switch/3s)
kA
20
20
Rated short-time withstand current(Earthing switch/2s)
kA
20
20
Rated peak withstand current(Load break switch)
kA
50
50
Rated peak withstand current(Earthing switch)
kA
50
50
Rated short-circuit making current(Load break switch)
kA
50
125
Rated short-circuit making current(Earthing switch)
kA
50
50
Rated closed-loop dropout current
A
630
 
Rated active load breaking current
A
630
 
Rated cable-charging breaking current
A
10
10
Rated short-circuit breaking current
kA
 
50*
Rated transfer current
A
 
1750*
Fuse type
 
 
XRNT-12kV/125A*
Fuse impact output energy
J
 
1±0.5
Mechanical endurance LBS/Earthing switch
Time
5000/2000
5000
Air insulation distance of charged body and ground
mm
≥ 125
≥ 125
SF6 Gas pressure(Relative pressure at 20ºC )
bar
0.4
0.4
Opening and Closing simultaneity
ms
≤ 2
≤ 2
Main circuit resistance
μΩ
≤ 65
≤ 65

 

Basic functions and features:

1.Load breaker switch adapts double fracture, rotary movable contact structure, with the following three kinds of operating states: Closing,opening,earthing.
2.Using SF6 gas as an arc extinguishing and insulating medium, the main circuit seals by the upper and lower housing pouring epoxy resin, the conductive function is unaffected by external influences.
3.Good safety performance. If internal arcing occurs, the housing has an internal structure weak point, it will be rushed to open, followed by the cabinet above the shutter release arc red open air overpressure stream-oriented outside the cabinet, ensure that the switch cabinet security checks.
4.Load breaker switch sets gates, opening, earthing switch three at one, filled with SF6 gas encapsulated in epoxy resin housing, three-position interlock,compact structure,high security and reliability.
5.Small size, light weight, maintenance-free, easy and safe to operate.
 

Normal working Environment

 1. Altitude: ≤1000m

 2. Ambient temperature at -30ºC to +40ºC, the daily average temperature should not more than 30ºC.

 3. The daily average of relative humidity is less than 95%, the average monthly is less than 90%.

 4. Working environment should be without steam, gas, chemical corrosive deposition, salt fog, dust, dirt and other dangerous explosive media, which will severely impact on insulation and conductivity of products.

 5. Working environment should not be regular vibration or serious bumps.
 

Structure

12kv 200mm 3 Phase Switch with Manual Operating Mechanism Sf6 Lbs Air Load Break Switch
12kv 200mm 3 Phase Switch with Manual Operating Mechanism Sf6 Lbs Air Load Break Switch




Application
12kv 200mm 3 Phase Switch with Manual Operating Mechanism Sf6 Lbs Air Load Break Switch
Optional Accessories
12kv 200mm 3 Phase Switch with Manual Operating Mechanism Sf6 Lbs Air Load Break Switch

12kv 200mm 3 Phase Switch with Manual Operating Mechanism Sf6 Lbs Air Load Break Switch12kv 200mm 3 Phase Switch with Manual Operating Mechanism Sf6 Lbs Air Load Break Switch12kv 200mm 3 Phase Switch with Manual Operating Mechanism Sf6 Lbs Air Load Break Switch12kv 200mm 3 Phase Switch with Manual Operating Mechanism Sf6 Lbs Air Load Break Switch12kv 200mm 3 Phase Switch with Manual Operating Mechanism Sf6 Lbs Air Load Break Switch12kv 200mm 3 Phase Switch with Manual Operating Mechanism Sf6 Lbs Air Load Break Switch

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier