FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
18
Year of Establishment
2011-04-07
  • FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023
  • FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023
  • FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023
  • FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023
  • FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023
  • FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023
Find Similar Products

Basic Info.

Model NO.
FL(R)N48-12
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
SF6
Installation
Fixed
Structure
Lbs
Certification
ISO9001-2000
Voltage
12kv
Current
630A
Frequency
50Hz
Phase Distance
210mm
Altitude
Not Higher Than 2000m
Transport Package
Standard Export Shipping Package
Trademark
LIYOND
Origin
Zhejiang, China
Production Capacity
1000 Pieces/Month

Product Description

FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023
FL(R)N48-12 12kv 630A 210mm High Voltage Indoor SF6 Load Break Switch for RMU Ring Main Unit


Summary:
FLN36/48- 12D/T630-25 indoor AC high voltage SF6 load switch and FLRN36/48- 12D/T1250-31.5 indoor AC high voltage SF6 load switch fuse combination apparatus is suitable for three-phase 50Hz ring network or terminal power supply and industrial electrical equipment, for protecting the line of 10kV Electric Power Load Control System.
The load switch can be divided into load current, closed loop current, no-load transformer and cable charging current;
The combined apparatus is capable of breaking any current which is reach to rated short circuit, and is suitable for the electrical equipment of the ring network unit, the box type substation and so on.
The utility model is especially suitable for places such as the distribution of the urban residential areas, the small two substations, the opening and closing stations, the industrial and mining enterprises, large shopping malls, airports, subways, hospitals, stadiums, etc.

Ambient condition:

1.Altitude: ≤2000m
2.Ambient temperature: -40°C ~+40°C
3.Earthquake intensity: ≤8 degree
4.Relative humidity: Daily averages ≤95%, Monthly average≤90%


Parameters:
Item Unit Data
FLN48-12D/T630-25 FLRN48-12D/T1250-31.5
Rated voltage kV 12
Rated frequency Hz 50
Rated current A 630 1250
Rated active load breaking current 630  
Rated closed loop dropout current 630  
Rated transfer current   1700
Lightning impulse withstand voltage(peak) kV phase to earth, between phase 75, fracture 85
1 min power frequency withstand voltage phase to earth, between phase 42, fracture 48
Rated short-time withstand current(2s) kA 25
Rated peak withstand current 63
Rated short-circuit closing current(peak) 63 80(expected)
Fuse type     S LAJ-12
Output energy of impactor J   1+0.5
Mechanical life Load switch times 5000
Earth switch 2000

FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023
More types:
FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023

FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023
FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023


FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023
FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023
FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023

FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023FL (R) N48-12 12kv 630A 210mm High Voltage Indoor Sf6 Load Break Switch for Rmu Ring Main Unit 2023
FAQ:
Q: Could I have prices of your products?
A: Welcome. Please feel free to send us inquiry here. We will reply you within 24 hours.

Q: Can I get a sample before the bulk order?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.

Q: Can we print our logo/ company name on products?
A: Yes, of course, we accept OEM, then need you to provide brand authorization to us.

Q:Do you accept product customization?
A:Yes, of course, please provide specific drawings or parameters, we will quote you after evaluation.

Q: What is the lead time? 
A: The lead time depends on the quantities ordered, generally within 7-20 days after receiving the payment. 

Q: What is your Trade Terms? 
A: We accept EXW, FOB, CIF, FCA, etc. 

Q: What is your payment method?  
A: We accept T/T, Western Union, Paypal, etc.

Q: Do you inspect the finished products?
A: Yes, each step of production and finished products will be came out inspection by QC department before shipping. And we will provide goods inspection reports for your reference before shipment

Q: How to solve the quality problems after sales? 
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier