12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet

Product Details
Customization: Available
Certification: ISO9001
Shell Material: Stainless Steel
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
18
Year of Establishment
2011-04-07
  • 12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet
  • 12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet
  • 12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet
  • 12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet
  • 12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet
  • 12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet
Find Similar Products
  • Overview
  • FAQ
Overview

Basic Info.

Model NO.
LY-12(CCFC)
Installation
Fixed
Structure
Cabinet
Current
DC
Rated Voltage
12kv
Rated Current
630/1250A
Install
Indoor
OEM
Accept
Transport Package
Packages
Specification
12kv
Trademark
LIYOND
Origin
China

Product Description

12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet
12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet

LY-12 gas insulated switchgear series is a compact metal-sealed switchgear system for 12KV power distribution system. The switchgear is uniquely flexible due to its expandability, enabling full and semi-modular combinations.

The stainless steel gas chamber of the LY-12 gas insulated switchgear equipment is filled with SF6 gas, which completely seals all the live parts and the switch, and isolates them from the outside world. This fully-sealed structure keeps the internal switches and live parts from being affected by changes in the external environment, ensuring the reliability, safety and maintenance-free nature of the equipment.
The basic module scheme forms are: C, F, V, D, De.
The code description is as follows:
C: Two-position load break switch unit with earthing switch
F: Load break switch-fuse combination module
V: Vacuum switch module with earthing switch and two-position load (isolating) switch
D: Cable connection module without earthing switch
De: Cable connection module with earthing switch

 


Structure 
12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet
Working Conditions

1. Ambient air temperature: upper limit +40 °C lower limit -40 °C;
2. Air relative humidity: the daily average is not more than 95%, and the monthly average is not more than 90%;
3. Altitude ≤ 1500 meters (under standard inflation pressure);
4. The seismic intensity does not exceed 8;
5. Places without fire, explosion, serious pollution, chemical corrosion and severe vibration.

 

Special conditions
Manufacturer and end user must agree on special operating conditions that differ from normal operating conditions.
If particularly harsh operating environments are involved, the manufacturer and supplier must be consulted.
When the electrical equipment is installed above 1500 meters above sea level, it should be specified so that the pressure can be adjusted during manufacture. When this pressure is adjusted, the life of the switchgear itself has no significant effect.



Main technical parameters:
 
Item Unit C module F module V module
Load break Switch Combination
apparatus
Vacuum
switch
Disconnecting/

 

earthing switch

Rated voltage kV 12 12 12 12
Rated frequency Hz 50 50 50 50
Power frequency withstand voltage
(interphase/fracture)
kV 42/48 42/48 42/48 42/48
Lightning impulse withstand voltage kV 75/85 75/85 75/85 75/85
Rated current A 630 * 630 630
Rated closed loop breaking current A 630      
Rated cable charged breaking current A 10      
Rated short-circuit making curemt (peak) A 50 80    
Rated peak withstand current kA 50      
Rated short time withstand current kA/4s 20      
Rated short circuit breaking current kA   31.5 20  
Rated transfer current A   1700    
Maximum current with fuse A - 125    
Loop resistance Ω ≤300 ≤600    
Mechanical life Times 5000 3000 5000 2000

*Depends on fuse rated current value.

 
Ordering Instructions
The user must provide the following technical information when ordering:
1. Main circuit diagram, arrangement diagram and floor plan;
2. Schematic diagram of the secondary circuit of the switch cabinet;
3. Models, specifications and quantities of all electrical components in the switchgear;
4. If you need to set up a low-voltage box, it should be explained;
5. When the switch cabinet is used in special environmental conditions, it should be explained.

More types
12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet

 

 

12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet12kv Sf6 Gas Insulated Switchgear Ccfc Load Switch Cabinet
FAQ

Q: Could I have prices of your products?

A: Welcome. Please feel free to send us inquiry here. We will reply you within 24 hours.

 

Q: Can I get a sample before the bulk order?

A: Yes, we welcome sample order to test and check quality.Mixed samples are acceptable.

 

Q: Can we print our logo/ company name on products?

A: Yes, of course, we accept OEM, then need you to provide brand authorization to us

 

Q: Do you accept product customization?

A: Yes, of course, please provide specific drawings or parameters, we will quote you after evaluation


Q: What is the lead time? 
A: The lead time depends on the quantities ordered, generally within 7-20 days after receiving the payment. 

 

Q: What is your Trade Terms? 
A: We accept EXW, FOB, CIF, FCA, etc

 

Q: What is your payment method?  
A: We accept T/T, Western Union, Paypalirrevocable L/C at sight, etc 

 

Q: Do you inspect the finished products?

A: Yes, each step of production and finished products will be came out inspection by QC department before shipping. And we will provide goods inspection reports for your reference before shipment


Q: How to solve the quality problems after sales? 
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier