Breaking Capacity: | High Voltage Circuit Breakers |
---|---|
Operation: | Energy-storage Type |
Speed: | Normal Type Circuit Breaker |
Arc-extinguishing Medium: | Vacuum |
Installation: | Insert |
Structure: | Vcb |
Customization: |
---|
Suppliers with verified business licenses
The VSG-12 Model indoor high voltage 12kV 3 Pole High Voltage Vacuum Circuit Breaker is designed for power systems with a rated voltage of 12kv. It serves as a protective and control unit for power grid equipment and industrial power equipment. This circuit breaker can be used with KYN28(GZS1), XGN, GG-1A, and other types of switchgear panels. Related products include isolated handcart, fuse handcart, and voltage transformer handcart.
The VSG series of circuit breakers are suitable for rated voltages of 12-24kv, rated short circuit breaking currents of 20 and 50KA, and rated currents of 630-5000A for power distribution users. They have a mechanical endurance of 20000 operations and 50 operations at full capacity breaking ability at small current. These circuit breakers require minimal maintenance and are suitable for applications with frequent operation. They can be used with Model KYN28A(GZS1) metal-enclosed switchgear and other fixed or handcart cabinets.
Manufacturer: Yueqing Liyond Electric Co., Ltd.
No. | Name | Unit | Data | ||||||
1 | Rated voltage | kV | 12 | ||||||
2 | Rated current | A | 630 | 1000 1250 | 1600 2000 2500 3150 | ||||
3 | Rated short circuit breaking current | kA | 20 | 25 | 20 | 25 | 31.5 | 31.5 | 40 |
4 | Rated peak withstand current | kA | 50 | 63 | 50 | 63 | 80 | 80 | 100 |
5 | Rated short time withstand current | kA | 20 | 25 | 20 | 25 | 31.5 | 31.5 | 40 |
6 | Rated short circuit making current | kA | 50 | 63 | 50 | 63 | 80 | 80 | 100 |
7 | Switching operations of short circuit current | times | 50 | ||||||
8 | Rated operating sequence | O-0.3s-CO-180s-CO-180s-CO(40KA) | |||||||
9 | Mechanical endurance | times | 10000 | ||||||
10 | Rated breaking operations of the rated current | times | 20000 | ||||||
11 | Rated lighting impulse withstand voltage(full wave) | kV | 75 | ||||||
12 | 1 min. rated power frequency withstand voltage | kV | 42 | ||||||
13 | Contact stroke | mm | 9±1 | ||||||
14 | Over-travel of contacts | mm | 3.5±0.5 | ||||||
15 | Closing speed | m/s | 0.4∼0.8 | ||||||
16 | Opening speed | m/s | 0.9∼1.2 | ||||||
17 | Contact bouncing duration at closing operation | ms | ≤2 | ||||||
18 | Simultaneity of three phase closing operation | ms | ≤2 | ||||||
19 | Closing time | ms | 30∼70 | ||||||
20 | Opening time | m/s | 20∼50 | ||||||
21 | Distance between phases | mm | 150, 210, 275 | ||||||
22 | D.C component | 50% |
Yueqing Liyond Electric Co., Ltd. presents the Medium Voltage Fixed Type VCB Circuit Breaker, ideal for indoor use with a rated current of 4000A. Ensure cold wind is provided for optimal performance.