Well Sealed Vacuum Interrupter 12kv Applied for High Voltage Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: as Specification
Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
18
Year of Establishment
2011-04-07
Find Similar Products
  • Overview
  • FAQ
Overview

Basic Info.

Model NO.
12/2000
Speed
as Specification
Arc-extinguishing Medium
Vacuum
Installation
Insert
Structure
Vcb
Poles Number
3
Type
Vacuum Interrupter
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE
Rated Frequency
50/60Hz
Color
White
Transport Package
Carton
Specification
as specification
Trademark
Liyond
Origin
China
HS Code
8538900000
Production Capacity
5000/Year

Product Description


Well Sealed Vacuum Interrupter 12kv Applied for High Voltage Circuit Breaker

 

Well Sealed Vacuum Interrupter 12kv Applied for High Voltage Circuit Breaker
 
Well Sealed Vacuum Interrupter 12kv Applied for High Voltage Circuit Breaker

Vacuum interrupter, also known as vacuum switch tube, is the core component of the medium and high voltage power switch, its main role is that, through the excellent insulation of the vacuum inside the tube to make the medium and high voltage circuit cut off the power supply can quickly extinguish the arc and inhibit the current, to avoid accidents and accidents, mainly used in power transmission and distribution control systems, but also used in metallurgy, mining, petroleum, chemical, railway, broadcasting, communications, industrial high frequency heating and other power distribution system. It has the characteristics of energy saving, material saving, fire prevention, explosion-proof, small volume, long life, low maintenance cost, reliable operation and no pollution. The vacuum interrupter room is divided into interrupter room for circuit breaker and interrupter room for load switch. The interrupter room for circuit breaker is mainly used for substation and grid facilities in the electric power sector, and the interrupter room for load switch is mainly used for end users of the grid.

The outer casing of the vacuum interrupter is made of insulating material (ceramic or glass), and the two ends are sealed with a metal cover to form a closed container. There are a pair of contacts inside, the static contact is fixed on the static conductive rod, and the movable contact is fixed. On the moving rod. Since the bellows is sealed between the movable conductive rod and the metal cover, the movable conductive rod can move in the axial direction to drive the contacts to complete the splitting and closing action.

 

The bellows of the vacuum interrupter chamber is mainly responsible for ensuring the movement of the dynamic electrode within a certain range and maintaining a high vacuum for a long time, as well as ensuring that the vacuum interrupter chamber has a high mechanical life.
The bellows of the vacuum interrupter is a thin-walled component made of stainless steel with a thickness of 0.1 to 0.2 mm. In the process of dividing and closing the vacuum switch, the bellows of the interrupter chamber is subjected to expansion and contraction, and the bellows section is subjected to variable stress, so the life of the bellows should be determined according to the repeated expansion and contraction and the use of pressure.
The fatigue life of the bellows is related to the working conditions of the heated temperature. After the vacuum interrupter chamber has broken up a large short-circuit current, the residual heat of the conductive rod is transferred to the bellows, causing the temperature of the bellows to rise, and when the temperature rise reaches a certain level, this affects the fatigue strength of the bellows.

We supply many types. (250A, 2.5KA), (400A, 4KA), (400A, 6.3KA), (630A, 6.3KA), (1250A, 2.5KA), (1250A, 4KA), (1250A, 6.3K


Technica information:

Model Name

Vacuum Interrupter Bottle For High Voltage Circuit breaker

Brand Liyond
Type Circuit Breaker 
Application High Voltage Switchgear
Rated Voltage 12kV
Product Certification CE and ISO 9001:2000
Rated frequency 50Hz
Rated current 250/400/630A
Packing: 1. Each one is wrapped with plastic film

2. Packed in cartons

3.Cartons are sealed in a wooden box

 

4.The cases are bound with iron belts externally

Loading port: Shanghai Port/ Ningbo Port
Payment terms: L/C,T/T, Western Union
Delivery time: within 15 days, depends on order quantity
Additional:

1. OEM are welcome

2. High quality & timely delivery

3. Reasonable price

4. In a variety of designs and Specification


Well Sealed Vacuum Interrupter 12kv Applied for High Voltage Circuit BreakerWell Sealed Vacuum Interrupter 12kv Applied for High Voltage Circuit Breaker

Well Sealed Vacuum Interrupter 12kv Applied for High Voltage Circuit BreakerWell Sealed Vacuum Interrupter 12kv Applied for High Voltage Circuit Breaker

Well Sealed Vacuum Interrupter 12kv Applied for High Voltage Circuit BreakerWell Sealed Vacuum Interrupter 12kv Applied for High Voltage Circuit Breaker

FAQ
 

Q: Could I have prices of your products?

A: Welcome. Please feel free to send us inquiry here. We will reply you within 24 hours.

 

Q: Can I get a sample before the bulk order?

A: Yes, we welcome sample order to test and check quality.Mixed samples are acceptable.

 

Q: Can we print our logo/ company name on products?

A: Yes, of course, we accept OEM, then need you to provide brand authorization to us

 

Q:Do you accept product customization?

A:Yes, of course, please provide specific drawings or parameters, we will quote you after evaluation


Q: What is the lead time? 
A: The lead time depends on the quantities ordered, generally within 7-20 days after receiving the payment. 

 

Q: What is your Trade Terms? 
A: We accept EXW, FOB, CIF, FCA, etc

 

Q: What is your payment method?  
A: We accept T/T, Western Union, Paypal, irrevocable L/C at sight, etc 

 

Q: Do you inspect the finished products?

A: Yes, each step of production and finished products will be came out inspection by QC department before shipping. And we will provide goods inspection reports for your reference before shipment


Q: How to solve the quality problems after sales? 
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier