• Zw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles Recloser
  • Zw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles Recloser
  • Zw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles Recloser

Zw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles Recloser

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: Auto Recloser
Customization:
Diamond Member Since 2009

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
ZW32-12
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000
Rated Voltage
12kv
Rated Current
630A
Application
Outdoor
Arc-Extinguishing
Vacuum
Rated Short Circuit Breaking Current
20/25/31.5ka
Mechanical Life
10000 Times
Transport Package
Standard Export Packaging
Specification
as specification
Trademark
Liyond
Origin
China
Production Capacity
10000 Set/Month

Product Description

Zw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles Recloser

Zw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles RecloserZw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles Recloser
 

Designed on the basis of ZW32 vacuum circuit breaker, the integrated solid-sealed pole combines a variety of advanced power equipment construction technology, micro-power electronic sensing technology, wireless communication technology, on-line power collection technology, etc.; up to 11 integrated voltage and current sensors (power-side three-phase voltage, load-side three-phase voltage, three-phase current, zero-sequence voltage and zero-sequence current). Single-phase power 10W, less than 10pC local discharge, side and bottom operation windows, more convenient operation.

The main configuration of ZW32 circuit breaker includes line online monitoring software, mobile phone APP, energy extraction unit, FTU automation terminal, and deeply fused circuit breaker. The product is widely used in 10kV urban and rural distribution overhead ring network line for dividing, sectioning and contacting switches, and it can realise the automated switching device for load deployment of the ring network line.

 

 

Main technical parameters of circuit breaker

S/N Item Unit Data
1 Rated voltage kV 12
2 Rated current A 630
3 1min power frequency withstand voltage Dry test: phase to phase, ground/fracture kV 42/48
Wet test: phase to phase, ground/fracture kV 34
4 Lightning impulse withstand voltage (peak value) phase to phase, ground/fracture kV 75/85
5 Rated short circuit breaking current kV 20/25
6 Rated short circuit making current (peak value) kA 50/63
7 Rated peak withstand current kA 50/63
8 4s short-term withstand current kA 20/25
9 Rated operating sequence - O-0.3s-CO-180s-CO
10 Rated short circuit current breaking times times 30
11 Mechanical life times 10000
12 Energy storage motor rated voltage V DC24
13 Energy storage motor rated power W 70
14 Rated operating voltage V DC24
15 Energy storage time at rated voltage S <10
16 Partial discharge of the whole machine Pc <10

 


Normal use conditions
1. Altitude not exceeding 1000m;
2. Ambient temperature not exceeding ±40°C;
3. Seismic intensity not exceeding 8 degrees;
4. Maximum wind speed should not exceed 35m/s. 
5. There should be no explosion, no corrosive harmful gas that destroys insulation, and no violent vibration;
6. the thickness of ice cover does not exceed 10mm.
For special conditions of use, please make specific instructions at the time of ordering, so that the insulation level and other capabilities of the circuit breaker can be corrected. Specific parameters are subject to actual delivery.

 

Application
Zw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles Recloser

Instructions for ordering
1) Model, name and quantity of circuit breaker;
2) Rated voltage, rated current and rated short-circuit breaking current of the circuit breaker;
3) Operation mode of operating mechanism (manual, electric, with remote control), type and rated value of operating power supply;
4) Current transformer accuracy level, ratio, quantity;
5) Name and quantity of spare parts;
6) Other special requirements.

Zw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles Recloser

Zw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles RecloserZw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles RecloserZw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles RecloserZw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles Recloser
Zw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles Recloser
Zw32-12 Type Pole-Mounted Circuit Breakers Integral Sealed Poles Recloser

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now